res:
  bibo_abstract:
  - Stereological methods for estimating the 3D particle size and density from 2D
    projections are essential to many research fields. These methods are, however,
    prone to errors arising from undetected particle profiles due to sectioning and
    limited resolution, known as ‘lost caps’. A potential solution developed by Keiding,
    Jensen, and Ranek in 1972, which we refer to as the Keiding model, accounts for
    lost caps by quantifying the smallest detectable profile in terms of its limiting
    ‘cap angle’ (ϕ), a size-independent measure of a particle’s distance from the
    section surface. However, this simple solution has not been widely adopted nor
    tested. Rather, model-independent design-based stereological methods, which do
    not explicitly account for lost caps, have come to the fore. Here, we provide
    the first experimental validation of the Keiding model by comparing the size and
    density of particles estimated from 2D projections with direct measurement from
    3D EM reconstructions of the same tissue. We applied the Keiding model to estimate
    the size and density of somata, nuclei and vesicles in the cerebellum of mice
    and rats, where high packing density can be problematic for design-based methods.
    Our analysis reveals a Gaussian distribution for ϕ rather than a single value.
    Nevertheless, curve fits of the Keiding model to the 2D diameter distribution
    accurately estimate the mean ϕ and 3D diameter distribution. While systematic
    testing using simulations revealed an upper limit to determining ϕ, our analysis
    shows that estimated ϕ can be used to determine the 3D particle density from the
    2D density under a wide range of conditions, and this method is potentially more
    accurate than minimum-size-based lost-cap corrections and disector methods. Our
    results show the Keiding model provides an efficient means of accurately estimating
    the size and density of particles from 2D projections even under conditions of
    a high density.@eng
  bibo_authorlist:
  - foaf_Person:
      foaf_givenName: Jason Seth
      foaf_name: Rothman, Jason Seth
      foaf_surname: Rothman
  - foaf_Person:
      foaf_givenName: Carolina
      foaf_name: Borges Merjane, Carolina
      foaf_surname: Borges Merjane
      foaf_workInfoHomepage: http://www.librecat.org/personId=4305C450-F248-11E8-B48F-1D18A9856A87
    orcid: 0000-0003-0005-401X
  - foaf_Person:
      foaf_givenName: Noemi
      foaf_name: Holderith, Noemi
      foaf_surname: Holderith
  - foaf_Person:
      foaf_givenName: Peter M
      foaf_name: Jonas, Peter M
      foaf_surname: Jonas
      foaf_workInfoHomepage: http://www.librecat.org/personId=353C1B58-F248-11E8-B48F-1D18A9856A87
    orcid: 0000-0001-5001-4804
  - foaf_Person:
      foaf_givenName: R.
      foaf_name: Angus Silver, R.
      foaf_surname: Angus Silver
  bibo_doi: 10.1371/journal.pone.0277148
  bibo_issue: 3 March
  bibo_volume: 18
  dct_date: 2023^xs_gYear
  dct_identifier:
  - UT:001024737400001
  dct_isPartOf:
  - http://id.crossref.org/issn/1932-6203
  dct_language: eng
  dct_publisher: Public Library of Science@
  dct_title: Validation of a stereological method for estimating particle size and
    density from 2D projections with high accuracy@
  fabio_hasPubmedId: '36930689'
...