X10 expansion microscopy enables 25‐nm resolution on conventional microscopes

Truckenbrodt SM, Maidorn M, Crzan D, Wildhagen H, Kabatas S, Rizzoli SO. 2018. X10 expansion microscopy enables 25‐nm resolution on conventional microscopes. EMBO reports. 19(9), e45836.

Download
OA 2018_embo_Truckenbrodt.pdf 2.01 MB [Published Version]

Journal Article | Published | English

Scopus indexed
Author
Truckenbrodt, Sven MISTA; Maidorn, Manuel; Crzan, Dagmar; Wildhagen, Hanna; Kabatas, Selda; Rizzoli, Silvio O
Department
Abstract
Expansion microscopy is a recently introduced imaging technique that achieves super‐resolution through physically expanding the specimen by ~4×, after embedding into a swellable gel. The resolution attained is, correspondingly, approximately fourfold better than the diffraction limit, or ~70 nm. This is a major improvement over conventional microscopy, but still lags behind modern STED or STORM setups, whose resolution can reach 20–30 nm. We addressed this issue here by introducing an improved gel recipe that enables an expansion factor of ~10× in each dimension, which corresponds to an expansion of the sample volume by more than 1,000‐fold. Our protocol, which we termed X10 microscopy, achieves a resolution of 25–30 nm on conventional epifluorescence microscopes. X10 provides multi‐color images similar or even superior to those produced with more challenging methods, such as STED, STORM, and iterative expansion microscopy (iExM). X10 is therefore the cheapest and easiest option for high‐quality super‐resolution imaging currently available. X10 should be usable in any laboratory, irrespective of the machinery owned or of the technical knowledge.
Publishing Year
Date Published
2018-09-01
Journal Title
EMBO reports
Publisher
Embo Press
Volume
19
Issue
9
Article Number
e45836
ISSN
eISSN
IST-REx-ID

Cite this

Truckenbrodt SM, Maidorn M, Crzan D, Wildhagen H, Kabatas S, Rizzoli SO. X10 expansion microscopy enables 25‐nm resolution on conventional microscopes. EMBO reports. 2018;19(9). doi:10.15252/embr.201845836
Truckenbrodt, S. M., Maidorn, M., Crzan, D., Wildhagen, H., Kabatas, S., & Rizzoli, S. O. (2018). X10 expansion microscopy enables 25‐nm resolution on conventional microscopes. EMBO Reports. Embo Press. https://doi.org/10.15252/embr.201845836
Truckenbrodt, Sven M, Manuel Maidorn, Dagmar Crzan, Hanna Wildhagen, Selda Kabatas, and Silvio O Rizzoli. “X10 Expansion Microscopy Enables 25‐nm Resolution on Conventional Microscopes.” EMBO Reports. Embo Press, 2018. https://doi.org/10.15252/embr.201845836.
S. M. Truckenbrodt, M. Maidorn, D. Crzan, H. Wildhagen, S. Kabatas, and S. O. Rizzoli, “X10 expansion microscopy enables 25‐nm resolution on conventional microscopes,” EMBO reports, vol. 19, no. 9. Embo Press, 2018.
Truckenbrodt SM, Maidorn M, Crzan D, Wildhagen H, Kabatas S, Rizzoli SO. 2018. X10 expansion microscopy enables 25‐nm resolution on conventional microscopes. EMBO reports. 19(9), e45836.
Truckenbrodt, Sven M., et al. “X10 Expansion Microscopy Enables 25‐nm Resolution on Conventional Microscopes.” EMBO Reports, vol. 19, no. 9, e45836, Embo Press, 2018, doi:10.15252/embr.201845836.
All files available under the following license(s):
Creative Commons Attribution 4.0 International Public License (CC-BY 4.0):
Main File(s)
Access Level
OA Open Access
Date Uploaded
2019-05-28
MD5 Checksum
6ec90abc637f09cca3a7b6424d7e7a26


Export

Marked Publications

Open Data ISTA Research Explorer

Web of Science

View record in Web of Science®

Search this title in

Google Scholar