Sensitivity-enhanced IPAP-SOFAST-HMQC for fast-pulsing 2D NMR with reduced radiofrequency load
Kern T, Schanda P, Brutscher B. 2008. Sensitivity-enhanced IPAP-SOFAST-HMQC for fast-pulsing 2D NMR with reduced radiofrequency load. Journal of Magnetic Resonance. 190(2), 333–338.
Download
No fulltext has been uploaded. References only!
Journal Article
| Published
| English
Author
Kern, Thomas;
Schanda, PaulISTA ;
Brutscher, Bernhard
Abstract
The SOFAST-HMQC experiment [P. Schanda, B. Brutscher, Very fast two-dimensional NMR spectroscopy for real-time investigation of dynamic events in proteins on the time scale of seconds, J. Am. Chem. Soc. 127 (2005) 8014–8015] allows recording two-dimensional correlation spectra of macromolecules such as proteins in only a few seconds acquisition time. To achieve the highest possible sensitivity, SOFAST-HMQC experiments are preferably performed on high-field NMR spectrometers equipped with cryogenically cooled probes. The duty cycle of over 80% in fast-pulsing SOFAST-HMQC experiments, however, may cause problems when using a cryogenic probe. Here we introduce SE-IPAP-SOFAST-HMQC, a new pulse sequence that provides comparable sensitivity to standard SOFAST-HMQC, while avoiding heteronuclear decoupling during 1H detection, and thus significantly reducing the radiofrequency load of the probe during the experiment. The experiment is also attractive for fast and sensitive measurement of heteronuclear one-bond spin coupling constants.
Publishing Year
Date Published
2008-02-01
Journal Title
Journal of Magnetic Resonance
Publisher
Elsevier
Volume
190
Issue
2
Page
333-338
ISSN
IST-REx-ID
Cite this
Kern T, Schanda P, Brutscher B. Sensitivity-enhanced IPAP-SOFAST-HMQC for fast-pulsing 2D NMR with reduced radiofrequency load. Journal of Magnetic Resonance. 2008;190(2):333-338. doi:10.1016/j.jmr.2007.11.015
Kern, T., Schanda, P., & Brutscher, B. (2008). Sensitivity-enhanced IPAP-SOFAST-HMQC for fast-pulsing 2D NMR with reduced radiofrequency load. Journal of Magnetic Resonance. Elsevier. https://doi.org/10.1016/j.jmr.2007.11.015
Kern, Thomas, Paul Schanda, and Bernhard Brutscher. “Sensitivity-Enhanced IPAP-SOFAST-HMQC for Fast-Pulsing 2D NMR with Reduced Radiofrequency Load.” Journal of Magnetic Resonance. Elsevier, 2008. https://doi.org/10.1016/j.jmr.2007.11.015.
T. Kern, P. Schanda, and B. Brutscher, “Sensitivity-enhanced IPAP-SOFAST-HMQC for fast-pulsing 2D NMR with reduced radiofrequency load,” Journal of Magnetic Resonance, vol. 190, no. 2. Elsevier, pp. 333–338, 2008.
Kern T, Schanda P, Brutscher B. 2008. Sensitivity-enhanced IPAP-SOFAST-HMQC for fast-pulsing 2D NMR with reduced radiofrequency load. Journal of Magnetic Resonance. 190(2), 333–338.
Kern, Thomas, et al. “Sensitivity-Enhanced IPAP-SOFAST-HMQC for Fast-Pulsing 2D NMR with Reduced Radiofrequency Load.” Journal of Magnetic Resonance, vol. 190, no. 2, Elsevier, 2008, pp. 333–38, doi:10.1016/j.jmr.2007.11.015.